Pediatric PALS Sound Menu

Item No. 1018190 [W49417]
Weight 0.07kg
Dimensions 16 x 7 x 2 cm
MPN: ST2M-51
Category:

Description

Why Choose the Pediatric PALS Sound Menu for Your Simulation Lab in India?

The Pediatric PALS Sound Menu (Item No. 1018190 / W49417, MPN: ST2M-51, 0.07 kg, 16 × 7 × 2 cm) by Nasco Healthcare, USA is a rate-based arrhythmia recognition card for the W49407 auscultation simulator, built around Pediatric Advanced Life Support (PALS) rhythm assessment — training students to correlate heart rate directly with rhythm classification, a skill distinct from the lesion-focused auscultation cards elsewhere in the series.

The 16 tracks progress through the full pediatric rate spectrum: sinus bradycardia with PVCs at 38 and 54 bpm, sinus arrhythmia at 64 bpm, normal sinus rhythm at 76 bpm, progressively faster sinus rates at 109, 135, and 178 bpm, and SVT at 310 bpm — giving students a continuous rate reference for distinguishing normal pediatric tachycardia from pathological SVT. The remaining tracks cover the critical PALS algorithm rhythms: atrial flutter, atrial fibrillation, ventricular tachycardia, idioventricular rhythm, 3rd degree AV block, paced rhythm, and asystole — the rhythm recognition set that directly maps to PALS algorithm decision points.

For PALS-certified nursing staff, pediatric ICU/emergency training centres, and NMC-mandated pediatric emergency curricula in India, this card trains the specific rate-and-rhythm recognition skill PALS certification requires — distinct from the murmur and congenital lesion identification taught by the other cards in the series.

Why Buy from SEM Trainers? SEM Trainers & Systems is an authorized distributor of Nasco Healthcare products in India with over 30 years of experience supplying medical simulators and auscultation training accessories to 1,500+ institutions across 28 states. We provide pan-India delivery and dedicated after-sales support.

Q: How is this different from the other pediatric sound menu cards?
A: This card trains rate-based rhythm recognition for PALS algorithm decisions (bradycardia through tachycardia, arrest rhythms). The other pediatric cards in the series focus on murmurs and congenital lesion identification — a different clinical skill.

Q: Is this suitable for PALS certification preparation?
A: Yes — the rhythm set directly maps to PALS algorithm decision points, including the bradycardia and tachycardia rate thresholds and arrest rhythms.

Q: Which simulator is this compatible with?
A: The W49407 auscultation simulator.

Contact us at [email protected] or call +91-88495 63724 for pricing and availability.

Pediatric PALS Sound Menu – Auscultation Sounds for W49407

1. SB – PVCs 38 bpm
2. SB – PVCs 54 bpm
3. Sinus arrhythmia 64 bpm
4. NSR 76 bpm
5. Sinus 109 bpm
6. Sinus 135 bpm
7. Sinus tachycardia 178 bpm
8. SVT 310 bpm
9. Atrial flutter
10. Atrial fibrillation
11. Ventricular tachycardia
12. Ventricular tachycardia
13. Idioventricular
14. 3rd AV block
15. Paced rhythm
16. Asystole

 