Item No. BT-ACTB-LT
Weight
Make: BT Inc, South Korea
Category:

Description

– Simulator for adult resuscitation training and evaluation
– Lifelike body structure and silicon; Realistic training
– Various emergency simulation
– With various trauma modules, users can practice the trauma care (hemorrhage is possible)
– Rechargeable battery, completely wireless environment through Bluetooth communication
– Pupillary response; Patient assessment and evaluation
– While chest compression, it generates related pulse and check the ECG change from the patient monitor
– Possible to do chest compression and ventilation at the same time
– Palpate pulse at 4 sites (Bilateral carotid and femoral), possible to adjust the strength or turn on/off
– Virtual patient monitor layout can be adjusted by selecting needed items
– When running scenario, the current patient status can be jumped to the next status by using a transition
– Scenario, Checklist can be exported or imported
– The result data can be printed out by using a printer connected to a facilitator laptop
– The detailed CPR result and even log can be saved to Excel format
– The event log can be sorted by item or time order
– Designed in full compliance with the latest ERC 2025 and AHA guidelines.
– Software allows users to select or change the guidelines before each training session.

Trauma treatment wound module

– Amputated leg module (bleeding): Bleeding control using tourniquet is possible
– Open fractured leg module (bleeding)
– Open fracture arm module (bleeding)
– Attachable wound module (laceration, burn, open fracture, abrasion, bruise)
– Attachable wound module small size (laceration, burn, open fracture, abrasion, bruise)


EYES

– Light reflex / consensual slight reflex
– Adjust pupil size / Light reflex speed adjustment (Prompt/Slow)x
– Eyelids : Open/Closed (Manual)


Airway

– Head tilt/Chin lift, Jaw thrust maneuver
– Bag-valve-mask ventilation
– Airway intubation
: ETT/LMA/I-gel/Combi-tube insertion
: Detect the right main stem intubation
– Gastric intubation / Gastric inflation
– Check the force applied to the incisors
– Airway obstruction


Cardiac

– 3-4 Lead ECG
– Defibrillation and cardioversion
– Display Defibrillation shock rhythm/ CPR rhythm
– NIBP, ABP, PAP graphs through S/W
– Pulse palpation synchronized with ECG
: Bilateral carotid and femoral pulses
– Pulse strength adjustment (none / strong / moderate / weak)
– Body temperature (Software)


Breathing

– Spontaneous breathing
– Unilateral and bilateral chest rise and fall
– Normal Breathing sounds (Software)
– ETCO2 Capnography and SpO2 waveform through S/W


CPR real-time monitoring

– Compression depth and rate / incomplete recoil / hands-off time
– Hand position : Correct / Upper / Lower / Left / Right
– Ventilation volume and time / RR
– Chest compression & Ventilation at the same time


Vascular access

– IV (right arm)
– Medication (by S/W)


Speech

– Vocal sound

Reviews

There are no reviews yet.

Be the first to review “”

Your email address will not be published. Required fields are marked *

13 − one =